Skip to main content

CML400

Generate PDF

CML400
Description

COMMERCIAL CEILING-MOUNTED

Electronic control panel
Expansion by means of capillary tube
Cable for door heater (on low temperature units)
Cable for cold room light
Fixed calibration low pressure switch
High pressure switch on all three-phase
units and on single-phase CCM122-152
(in compliance with the “pressure equipment”
directive 97/23/CE)
Direct drainage of condensate water with heater
Hermetic compressor
Hot gas defrost
Filter on the liquid line
Remote control panel connected to the unit with a 5m long cable
Prearrangement for door micro switch connection

CML400

Technical data
Application LT
Coolant R452A
Expansion management Exp. Capillary
Brand SICAF
Compressor type E
Displacement 17,59 cc
Power absorption (W) 3180
Tension 400/3/50
 
Condenser fan 1X300 mm
Condenser air flow 1610 mc/h
Evaporator fans 1X300 mm
Evaporator air flow 1770 mc/h
Air throw m.7,5
 
Package W x D x H 900x740x1150 mm
Gross weight 120 Kg
 
Cooling capacity
Cold room temperature →
↓ Ambient temperature
-18°C -22°C -25°C
+20°C W
m3
3532
52,8
3077
43
2742
36,6
+32°C W
m3
2782
34,7
2362
27,6
2083
22,8
+43°C W
m3
2246
26,4
1810
20,3
1521
15,2