CMM058

Description
COMMERCIAL CEILING-MOUNTED
Electronic control panel
Expansion by means of capillary tube
Cable for door heater (on low temperature units)
Cable for cold room light
Fixed calibration low pressure switch
High pressure switch on all three-phase
units and on single-phase CCM122-152
(in compliance with the “pressure equipment”
directive 97/23/CE)
Direct drainage of condensate water with heater
Hermetic compressor
Hot gas defrost
Filter on the liquid line
Remote control panel connected to the unit with a 5m long cable
Prearrangement for door micro switch connection
CMM058
Technical data
Application
NT
Coolant
R452A
Expansion management
Exp. Capillary
Brand
SICAF
Compressor type
E
Displacement
2,49 cc
Power absorption (W)
920
Tension
230/1/50
Condenser fan
1X254 mm
Condenser air flow
1050 mc/h
Evaporator fans
1X200 mm
Evaporator air flow
550 mc/h
Air throw
m.5
Package W x D x H
650x600x930 mm
Gross weight 62 Kg
Cooling capacity
Cold room temperature → ↓ Ambient temperature |
+5°C | 0°C | -5°C | |
---|---|---|---|---|
+20°C |
W m3 |
1514 16,8 |
1290 13,3 |
1088 9,6 |
+32°C |
W m3 |
1216 12,7 |
1023 9,2 |
851 7,1 |
+43°C |
W m3 |
1006 8,2 |
838 5,8 |
696 4,7 |