Skip to main content

CMM058

Generate PDF

CMM058
Description

COMMERCIAL CEILING-MOUNTED

Electronic control panel
Expansion by means of capillary tube
Cable for door heater (on low temperature units)
Cable for cold room light
Fixed calibration low pressure switch
High pressure switch on all three-phase
units and on single-phase CCM122-152
(in compliance with the “pressure equipment”
directive 97/23/CE)
Direct drainage of condensate water with heater
Hermetic compressor
Hot gas defrost
Filter on the liquid line
Remote control panel connected to the unit with a 5m long cable
Prearrangement for door micro switch connection

CMM058

Technical data
Application NT
Coolant R452A
Expansion management Exp. Capillary
Brand SICAF
Compressor type E
Displacement 2,49 cc
Power absorption (W) 920
Tension 230/1/50
 
Condenser fan 1X254 mm
Condenser air flow 1050 mc/h
Evaporator fans 1X200 mm
Evaporator air flow 550 mc/h
Air throw m.5
 
Package W x D x H 650x600x930 mm
Gross weight 62 Kg
 
Cooling capacity
Cold room temperature →
↓ Ambient temperature
+5°C 0°C -5°C
+20°C W
m3
1514
16,8
1290
13,3
1088
9,6
+32°C W
m3
1216
12,7
1023
9,2
851
7,1
+43°C W
m3
1006
8,2
838
5,8
696
4,7