CMM120

Description
COMMERCIAL CEILING-MOUNTED
Electronic control panel
Expansion by means of capillary tube
Cable for door heater (on low temperature units)
Cable for cold room light
Fixed calibration low pressure switch
High pressure switch on all three-phase
units and on single-phase CCM122-152
(in compliance with the “pressure equipment”
directive 97/23/CE)
Direct drainage of condensate water with heater
Hermetic compressor
Hot gas defrost
Filter on the liquid line
Remote control panel connected to the unit with a 5m long cable
Prearrangement for door micro switch connection
CMM120
Technical data
Application
NT
Coolant
R452A
Expansion management
Exp. Capillary
Brand
SICAF
Compressor type
E
Displacement
4,56 cc
Power absorption (W)
1610
Tension
400/3/50
Condenser fan
2X254 mm
Condenser air flow
2100 mc/h
Evaporator fans
2X200 mm
Evaporator air flow
1100 mc/h
Air throw
m.5
Package W x D x H
900x650x980 mm
Gross weight 92 Kg
Cooling capacity
Cold room temperature → ↓ Ambient temperature |
+5°C | 0°C | -5°C | |
---|---|---|---|---|
+20°C |
W m3 |
3019 34 |
2525 26,7 |
2072 20 |
+32°C |
W m3 |
2440 27,1 |
2019 20,2 |
1634 15 |
+43°C |
W m3 |
2000 20,2 |
1677 15,1 |
1355 12,2 |