CMM200

Description
COMMERCIAL CEILING-MOUNTED
Electronic control panel
Expansion by means of capillary tube
Cable for door heater (on low temperature units)
Cable for cold room light
Fixed calibration low pressure switch
High pressure switch on all three-phase
units and on single-phase CCM122-152
(in compliance with the “pressure equipment”
directive 97/23/CE)
Direct drainage of condensate water with heater
Hermetic compressor
Hot gas defrost
Filter on the liquid line
Remote control panel connected to the unit with a 5m long cable
Prearrangement for door micro switch connection
CMM200
Technical data
Application
NT
Coolant
R452A
Expansion management
Exp. Capillary
Brand
SICAF
Compressor type
E
Displacement
7,57 cc
Power absorption (W)
2250
Tension
400/3/50
Condenser fan
1X300 mm
Condenser air flow
1610 mc/h
Evaporator fans
1X300 mm
Evaporator air flow
1770 mc/h
Air throw
m.7,5
Package W x D x H
900x740x1150 mm
Gross weight 110 Kg
Cooling capacity
Cold room temperature → ↓ Ambient temperature |
+5°C | 0°C | -5°C | |
---|---|---|---|---|
+20°C |
W m3 |
5284 81,7 |
4424 61,9 |
3727 47,8 |
+32°C |
W m3 |
4214 64 |
3501 47,1 |
2912 34,8 |
+43°C |
W m3 |
3342 42,1 |
2830 31,9 |
2335 24 |