HML150

Description
Commercial Split Units
Electronic control panel
Expansion by means of thermal expansion valve
Cable for door heater (on low temperature units)
Fixed calibration low pressure switch
High pressure switch on all three-phase units and on single-phase HMM122-152
(in compliance with the “pressure equipment” directive 97/23/CE)
Direct drainage of condensate water with heater
Hermetic compressor
Electric defrost
Filter on the liquid line
Remote control panel connected to the unit with a 5m long cable
Sight glass
All units are equiped with a liquid receiver complying (in compliance with the
“pressure equipment” directive 97/23/CE)
Pre-arrangement for door switch and room light connections
HML150
Technical data
Application
LT
Coolant
R452A
Expansion management
Exp. Valve
Brand
SICAF
Compressor type
E
Displacement
4,84 cc
Power absorption (W)
1350
Tension
230/1/50
Condenser fan
1X254 mm
Condenser air flow
1050 mc/h
Evaporator fans
1x254 mm
Evaporator air flow
810 mc/h
Air throw
m.6
Package W x D x H (C)
850x690x640 mm
Gross weight 71 Kg
Package W x D x H (E)
710x620x390 mm
Gross weight
20 Kg
Cooling capacity
Cold room temperature → ↓ Ambient temperature |
-18°C | -22°C | -25°C | |
---|---|---|---|---|
+20°C |
W m3 |
1465 12,9 |
1212 10,2 |
1043 7,9 |
+32°C |
W m3 |
1175 9,5 |
947 7,2 |
794 5,3 |
+43°C |
W m3 |
1015 7,5 |
807 5,8 |
665 4 |