Skip to main content

HML220

Generate PDF

HML220
Description

Commercial Split Units

Electronic control panel
Expansion by means of thermal expansion valve
Cable for door heater (on low temperature units)
Fixed calibration low pressure switch
High pressure switch on all three-phase units and on single-phase HMM122-152
(in compliance with the “pressure equipment” directive 97/23/CE)
Direct drainage of condensate water with heater
Hermetic compressor
Electric defrost
Filter on the liquid line
Remote control panel connected to the unit with a 5m long cable
Sight glass
All units are equiped with a liquid receiver complying (in compliance with the
“pressure equipment” directive 97/23/CE)
Pre-arrangement for door switch and room light connections

HML220

Technical data
Application LT
Coolant R452A
Expansion management Exp. Valve
Brand SICAF
Compressor type E
Displacement 9,26 cc
Power absorption (W) 1810
Tension 400/3/50
 
Condenser fan 1x300 mm
Condenser air flow 1610 mc/h
Evaporator fans 2x254 mm
Evaporator air flow 1590 mc/h
Air throw m.6
 
Package W x D x H (C) 850x690x640 mm
Gross weight 82 Kg
Package W x D x H (E) 1010x620x390 mm
Gross weight 28 Kg
 
Cooling capacity
Cold room temperature →
↓ Ambient temperature
-18°C -22°C -25°C
+20°C W
m3
2090
21,5
1745
16,5
1516
13,2
+32°C W
m3
1667
15,4
1360
11,5
1154
8,4
+43°C W
m3
1412
12,3
1143
9,1
956
6,6