HML300

Description
Commercial Split Units
Electronic control panel
Expansion by means of thermal expansion valve
Cable for door heater (on low temperature units)
Fixed calibration low pressure switch
High pressure switch on all three-phase units and on single-phase HMM122-152
(in compliance with the “pressure equipment” directive 97/23/CE)
Direct drainage of condensate water with heater
Hermetic compressor
Electric defrost
Filter on the liquid line
Remote control panel connected to the unit with a 5m long cable
Sight glass
All units are equiped with a liquid receiver complying (in compliance with the
“pressure equipment” directive 97/23/CE)
Pre-arrangement for door switch and room light connections
HML300
Technical data
Application
LT
Coolant
R452A
Expansion management
Exp. Valve
Brand
SICAF
Compressor type
E
Displacement
12,92 cc
Power absorption (W)
2400
Tension
400/3/50
Condenser fan
1X350 mm
Condenser air flow
2200 mc/h
Evaporator fans
3X254 mm
Evaporator air flow
2350 mc/h
Air throw
m.6
Package W x D x H (C)
930x790x750 mm
Gross weight 100 Kg
Package W x D x H (E)
1470x620x390 mm
Gross weight
40 Kg
Cooling capacity
Cold room temperature → ↓ Ambient temperature |
-18°C | -22°C | -25°C | |
---|---|---|---|---|
+20°C |
W m3 |
3046 37,9 |
2595 29,7 |
2772 23,7 |
+32°C |
W m3 |
2467 26 |
2045 19,4 |
1762 15,1 |
+43°C |
W m3 |
2082 21,1 |
1692 15,1 |
1442 11,8 |