HMM120

Description
Commercial Split Units
Electronic control panel
Expansion by means of thermal expansion valve
Cable for door heater (on low temperature units)
Fixed calibration low pressure switch
High pressure switch on all three-phase units and on single-phase HMM122-152
(in compliance with the “pressure equipment” directive 97/23/CE)
Direct drainage of condensate water with heater
Hermetic compressor
Electric defrost
Filter on the liquid line
Remote control panel connected to the unit with a 5m long cable
Sight glass
All units are equiped with a liquid receiver complying (in compliance with the
“pressure equipment” directive 97/23/CE)
Pre-arrangement for door switch and room light connections
HMM120
Technical data
Application
NT
Coolant
R452A
Expansion management
Exp. Valve
Brand
SICAF
Compressor type
E
Displacement
4,56 cc
Power absorption (W)
1610
Tension
400/3/50
Condenser fan
1X300 mm
Condenser air flow
1610 mc/h
Evaporator fans
2X254 mm
Evaporator air flow
1590 mc/h
Air throw
m.6
Package W x D x H (C)
850x690x640 mm
Gross weight 72 Kg
Package W x D x H (E)
1010x620x390 mm
Gross weight
28 Kg
Cooling capacity
Cold room temperature → ↓ Ambient temperature |
+5°C | 0°C | -5°C | |
---|---|---|---|---|
+20°C |
W m3 |
2925 35,4 |
2474 27,3 |
2126 21,2 |
+32°C |
W m3 |
2437 29,4 |
2131 22,3 |
1673 16,6 |
+43°C |
W m3 |
2111 20,7 |
1772 16,3 |
1458 13 |