ACL400

Description
Straddle mounting as standard, optional
panel through the wall installation
Electronic control instrument
Expansion device: capillary tube
Cable for door heater (on all low temperature units)
Cable for cold room lighting
Fixed calibration low pressure switch
High pressure switch on all three-phase
units and on single-phase models
ACM122-152 (this outfit complies with the
provisions of the “pressure equipment directive
97/23/CE)
Condensate evaporation tray with safety overflow drain
Drain heater
Hermetic compressor
Hot gas defrost
Filter on the liquid line
Prearrangement for door micro switch connection
Documenti generali
ACL400
Technical data
Application
LT
Coolant
R452A
Expansion management
Exp. Capillary
Brand
SICAF
Compressor type
E
Displacement
17,59 cc
Power absorption (W)
3180
Tension
400/3/50
Condenser fan
1X300 mm
Condenser air flow
1610 mc/h
Evaporator fans
1X300 mm
Evaporator air flow
1770 mc/h
Air throw
m.7,5
Package W x D x H
1160x840x1030 mm
Gross weight 131 Kg
Cooling capacity
Cold room temperature → ↓ Ambient temperature |
-18°C | -22°C | -25°C | |
---|---|---|---|---|
+20°C |
W m3 |
3532 52,8 |
3077 43 |
2742 36,6 |
+32°C |
W m3 |
2782 34,7 |
2362 27,6 |
2083 22,8 |
+43°C |
W m3 |
2246 26,4 |
1810 20,3 |
1521 15,2 |