Description

Straddle mounting as standard, optional
panel through the wall installation

Electronic control instrument
Expansion device: capillary tube
Cable for door heater (on all low temperature units)
Cable for cold room lighting
Fixed calibration low pressure switch
High pressure switch on all three-phase
units and on single-phase models
ACM122-152 (this outfit complies with the
provisions of the “pressure equipment directive
97/23/CE)
Condensate evaporation tray with safety overflow drain
Drain heater
Hermetic compressor
Hot gas defrost
Filter on the liquid line
Prearrangement for door micro switch connection

Documenti generali

ACM151

Technical data
Application NT
Coolant R452A
Expansion management Exp. Capillary
Brand SICAF
Compressor type E
Displacement 5,69 cc
Power absorption (W) 2020
Tension 400/3/50
 
Condenser fan 1X300 mm
Condenser air flow 1610 mc/h
Evaporator fans 1X300 mm
Evaporator air flow 1770 mc/h
Air throw m.7,5
 
Package W x D x H 1160x840x1030 mm
Gross weight 119 Kg
 
Cooling capacity
Cold room temperature →
↓ Ambient temperature
+5°C 0°C -5°C
+20°C W
m3
4472
67,7
3746
51,4
3154
39,3
+32°C W
m3
3556
52,7
2940
38,4
2442
28,8
+43°C W
m3
2825
34,8
2366
25,9
1949
19,5